JVC CL-R211 2MP 21.3-inch Clinical Review Display

  • Dynamic Gamma
  • Integrated QA Solution
  • Self-calibration
  • LED Indicator / Front Buttons
  • Built-in Sensor

Contact us directly for Volume Order Pricing and Shipping Rates. We offer special pricing and discounts on custom requirements and requests from Healthcare & Health System, Government, Purchasing Group facilities and OEM’s (Original Equipment Manufacturers).

Description

JVC CL-R211 2MP 21.3-inch Clinical Review Display Monitor

JVC CL-R211 2MP 21.3” Clinical Review Display is an optimal solution where doctors need to view both grayscale and color images, and effectively covers multiple applications like PACS, CAD, PET and nuclear medicine.

Dynamic Gamma — One Pixel Based Contrast and Brightness, Gamma

With the CL-R211 color images are automatically recognized to provide optimized contrast, brightness and gamma. No user intervention is required.

JVC CL-R211 Auto Text Mode — Auto Brightness Blinding Mode for Text Area 

Automatic brightness control for text data to reduce eye strain for patient lists and reporting application.

LED Backlight for Image Stability and Energy Saving

Compared to the conventional CCFL backlight models, JVC CL-R211 with LED backlight system saves energy and will hold brightness much longer. Additionally, mercury-free LED backlight contributes to reduce the environmental impacts.

JVC CL-R211 Built-in Sensor

With two built-in sensors for luminance stabilization and ambient light measurement, JVC CL-R211 consistently delivers unmatched image quality.

Ambient light sensor

An ambient light sensor is built-in so that calibration appropriate for the effects of ambient luminance is carried out.

Luminance sensor

The luminance sensor attached in front of the screen constantly monitors and accurately stabilizes luminance on the screen surface by sending feedback to the control circuit.

JVC CL-R211 Remote Calibration

DICOM conformance check and calibration can be remotely performed. These remote management features will minimize the burden of system administrators.

* Optional PM Medivisor software is required.

JVC CL-R211 DICOM Conformance Check

User friendly OSD functions include DICOM conformance check function.

Display Quality Control

The Medivisor Series software is user friendly tool to effectively manage JVCKENWOOD’s displays. Calibration software Medivisor Nx, quality assurance software QA Medivisor and performance monitoring software PM Medivisor interact closely with each other to help system administrators easily manage all JVCKENWOOD’s displays in the network.

DisplayPort

The CL-R211 implemented Display Port with 10 bit depth color in addition to conventional DVI input and achieved 1billion 64 million simultaneous color with 10 bit input.

Uniformity Equalizer

Luminance uniformity correction system will produce stable images across the screen.

User-selectable Display Configurations

Luminance/gamma settings are selectable from three preset levels according to the needs. User-selectable configuration enable stress free operations without specialized settings.

OSD Information Display

With a push of a button, the display’s current status can be checked such as the display model, total operating time, actual measurement of luminance, and calibration settings.

Display Status Indicator

Current display operating status can easily be checked by the front LED indicator.

JVC CL-R211 Worldwide Medical Safety Standards

JVC CLR211 meets worldwide medical safety standards.

Support

Brochure | JVC Healthcare | JVC Medical Displays | JVC Diagnostic Displays | JVC Surgical Displays | JVC Support

 

Specifications

Model Name
CL-R211
LCD Panel
Technology 21.3″ color TFT IPS technology
Display Area 324 mm x 432 mm
Pixel Pitch 0.270 mm x 0.270 mm
Contrast Ratio 1800:1(typ.)
Maximum
Luminance
500cd/㎡(typ.)
280 cd/㎡ ・ 250 cd/㎡ (calibrated)
Viewing Angle 178° vertical and horizontal
Visual Performance
Native Resolution 1200×1600
Display Colors 16.77 million colors from a palette of 68 billion colors
1.07 billion colors with DisplayPort and 10-bit viewer
Interface
Input Signal DVI-D(DVI 1.0 compliant)
DisplayPort(DisplayPort 1.2a compliant)
Plug and Play DDC2B compliant
Input Power Supply
Input Power Supply 100V-240V 50/60Hz
Maximum Power Consumption 45W(typ.)
Features
Calibration Control Luminance,Gamma,Color temperature
Capable of storing 3 sets of LUT
(Optional Calibration Kit is required)
OSD Information Display Model name, Serial No., Total operating time,
Calibration settings (Operating time since last calibration, Luminance, Gamma),
Current luminance, Color temperature and Ambient light, DICOM conformance
USB Hub USB Rev. 2.0 compliant, Self-powered
USB upstream connector (x1),
USB downstream connector (x2)
Other Features Uniformity Equalizer, Hardware pivot, LED indicator, DisplayPort Daisy Chains,
Advanced power management, Human Presence Sensor, Dynamic Gamma,
Auto Text Mode, Luminance stabilization, Multiple LUT, Self DICOM check, Self-calibration
Approvals
ANSI/AAMI ES 60601-1 (2005) + A1 (2012), CAN/CSA-C22.2 No. 60601-1 (2014), CE (EN 60601-1, EN 60601-1-2), RCM, FCC Part15 subpart B Class B, ICES-003-B, VCCI-B, FDA 510(k), J-Moss, RoHS, EAC, KC
Physical Characteristics
Dimensions
(W × H × D)
Landscape: 493 mm × 451.3 / 546.3 mm × 196.5 mm
Portrait: 361.5 mm × 517 / 612 mm × 196.5 mm
Weight 8.9 kg
Tilt Stand Tilt, Swivel, Portrait / Landscape
Mount VESA standard (100 mm x 100 mm)
Security Slot Anti-theft security slot
Accessories
Power cord, DisplayPort cable, USB cable, Operation manual,
Installation manual, Software(QA Medivisor Agent LE)

Additional information

Manufacturer

JVC KENWOOD CORPORATION

Model

CL-R211

P/N

CL-R211BN0UA

GTIN: 00046838078897