Home/Diagnostic Displays, Imaging, JVC, LCD, Mammography/JVC MS-S500-DH-M2000 5MP 21.3″ Dual Head Super High Bright Monochrome Mammography LCD Monitor

JVC MS-S500-DH-M2000 5MP 21.3″ Dual Head Super High Bright Monochrome Mammography LCD Monitor

Super High Resolution Display for Mammography
(Optional: Independent Subpixel Drive Technology)

The JVC MS-S500-DH-M2000 Dual Head LCD Monitor comes with 1,000 cd/㎡ calibration to make it the best solution for breast image diagnosis. With a maximum luminance of 3000 cd/㎡, a long lifetime is secured even in this preset. The brighter screen dramatically increases the number of perceptual grayscale steps to improve visibility of microcalcifications, tumors and structures.

PRICE REQUEST

Description

JVC MS-S500-DH-M2000 5MP 21.3″ Dual Head Super High Bright Monochrome Mammography LCD Monitor

JVC MS-S500-DH-M2000 Dual Head Monochrome LCD monitor comes with 1,000 cd/㎡2 calibration to make it the best solution for breast image diagnosis. With a maximum luminance of 3000 cd/㎡, a long lifetime is secured even in this preset. The brighter screen dramatically increases the number of perceptual grayscale steps to improve visibility of microcalcifications, tumors and structures.

Independent Sub-pixel Drive Technology
This unique technology enables JVC MS-S500-DH-M2000 LCD Monitor set to render 15 mega sub-pixel images, exceeding the current standards for primary breast image diagnosis. MS-S500 is cleared for FDA 510(k) for the use of digital mammography and breast tomosynthesis.

Auto Text Mode
Brightness is automatically adjusted on patient lists and reporting applications to reduce eye strain.

Improved Diagnostic Visibility
A contrast ration of 2000:1 delivers crisper images and gives radiologists confidence in breast image interpretation to improve work efficiency.

Image comparison

Integrated QA Solution
QA Medivisor Agent providing calibration and QA standard testing through a straightforward user interface is effective to manage daily operation.

* Optional calibration kit CAL-016 is required for standard QA testing.

Self-calibration
With the integrated color front sensor, JVC MS-S500-DH-M2000 LCD Monitor self-calibrates to the DICOM Part 14 Standard on a regular schedule.

Built-in Sensor

Premium Design
A simple and slim design for a modern look.

Protective Glass Filter
Glass filter with anti-reflect coating protects the LCD panel from dust or scratches.

Reading Light
Integrated reading light illuminates your keyboard.
The ambient sensor automatically adjusts the brightness to the room lighting conditions.

Space Saving
The new design of the JVC MS-S500-DH-M2000 LCD Monitor Dual Head set reduces 25% of the stand footprint compared to the conventional models.

Low Blue light Panel
The JVC MS-S500-DH-M2000 LCD Monitor set comes with a low blue light panel, which reduces strain on the eyes while reading.

Wire Management / DisplayPort Daisy Chains
With the DisplayPort 1.2, the use of daisy chains allows for easier wiring connections.

About JVC-Kenwood

JVC-Kenwood is a leading worldwide manufacturer of medical image displays and touch panel displays. Its high-end, high-cost-performance medical image displays and touch panels are backed by its unique technology and know-how through decades of solid experience in the industry since 1972.

JVC-Kenwood has supplied computer displays for factories, broadcast stations, workstations, and other applications, and has earned a high marks for its product reliability under harsh conditions and post-installation support, not to mention specialized technologies required for respective fields.

JVC-Kenwood continues to provide high-performance displays for specialized fields by developing leading-edge technologies, while providing consistently optimal customer service.

Model Name
MS-S500-DH-M2000
LCD Panel
Technology
21.3“ monochrome TFT IPS technology
Display Area
337.9 mm x 422.4 mm
Pixel Pitch
0.165 mm x 0.165 mm
Maximum Luminance
3000 cd/m² (typ.) 500 cd/m² / 1000 cd/m² (calibrated)
Contrast Ratio
2000:1 (typ.)
Viewing Angle
178° vertical and horizontal
Visual Performance
Native Resolution
2048 x 2560 (Independent Sub-pixel Drive technology ON : 2048 x 7680)
Display Colors
256 shades of grayscale are simultaneously displayed from a palette of 16,369 grayscale steps *1024 or 10-bit shades of grayscale with DisplayPort and 10-bit viewer *1276 shades of grayscale by using Independent Sub-pixel Drive technology
Interface
Input Signal
DVI-D (DVI 1.0 compliant) DisplayPort (DisplayPort 1.2a compliant)
Output Signal
DisplayPort (DisplayPort 1.2a compliant)
Plug and Play
DDC2B compliant
Input Power Supply
Input Power Supply
100V - 240 V 50/60 Hz
Maximum Power Consumption
80W (typ.)
Features
Calibration Control
Luminance, Gamma, Color temperature Capable of storing 3 sets of LUT (Optional Calibration Kit is required)
OSD Information Display
Model name, Serial No., Total operating time, Calibration settings (Operating time since last calibration, Luminance, Gamma), Current luminance, Color temperature and Ambient light, DICOM conformance
USB Hub
USB Rev.2 compliant, Self-powered USB upstream connector (x1), USB downstream connector (x2)
Other Features
Uniformity Equalizer, Hardware pivot, LED indicator, Advanced power management, Human Presence Sensor, Independent Sub-pixel Drive technology, Auto Text Mode, Reading light, Luminance stabilization, Multiple LUT, Self DICOM check, Self-calibration
Approvals
ANSI/AAMI ES60601-1 (2005) + A1 (2012), CAN/CSA-C22.2 No. 60601-1 (2014), CE (EN60601-1, EN60601-1-2), RCM, FCC Part15 subpart B Class B, ICES-003-B, VCCI-B, J-Moss, RoHS
FDA
510(k) Cleared to use for diagnostic purposes with digital medical images for Digital mammography PACS, Modalities including FFDM, and Breast tomosynthesis
Physical Characteristics
Dimensions(W x H x D)
Landscape : 493 mm x 451.3 / 546.3 mm x 196.5 mm Portrait : 361.5 mm x 517 / 612 mm x 196.5 mm
Weight
approx. 9.5 kg
Tilt Stand
Tilt, Swivel, Portrait / Landscape
Mount
VESA standard (100 mm x 100 mm)
Accessories
Power cord, DVI cable, DisplayPort cable, USB cable, Operation manual, Installation manual, Software (QA Medivisor Agent LE)

Warning: call_user_func() expects parameter 1 to be a valid callback, function 'download_file_force' not found or invalid function name in /home/hiliex.com/public_html/wp-content/plugins/woocommerce/templates/single-product/tabs/tabs.php on line 47