- 21.3″ 3MP Diagnostic LCD Monitor
- 1536 x 2048 Resolution
- Display Both Monochrome and Color
- Hassle-Free Multi-Monitor Configuration
- Dicom monitor with FDA 510(k) clearance
Eizo Radiforce RX360 21.3″ 3MP Color Diagnostic LCD Monitor
Description
Eizo Radiforce RX360 21.3″ 3MP Color Diagnostic LCD Monitor
The Eizo RX360 Diagnostic LCD monitors unique Work-and-Flow technology alleviates the complexity of the imaging workflow with new functions developed with the radiologist in mind. Users can take advantage of Work-and-Flow functions with the RadiForce monitor and bundled RadiCS LE software.
Quick Information Referencing
The Hide-and-Seek function on the Eizo Radiforce RX360 enables users to easily hide the PinP (Picture in Picture) window not currently in use and reopen it as needed by moving the mouse cursor to the edge of the screen or pressing a designated hotkey. This eliminates the need for an extra monitor while still allowing quick and efficient viewing of reports, patient charts, and other information.
Barrier-Free Workstyle
Switch-and-GoWith the Switch-and-Go function, you can operate two different workstations at the same time with a single mouse and keyboard. Work across several monitors by moving the cursor from one screen to the other or switch the signals between workstations as needed without having to change your mouse or keyboard each time. This makes it possible to reduce the number of monitors in the workflow and improves work efficiency.
Quick and Easy Focus
With the Point-and-Focus function on the Eizo Radiforce RX360 LCD monitor, you can quickly select and focus areas of your concern with just your mouse and keyboard. Change the brightness and grayscale tones of certain points on the screen to make interpretation easier.
Display Both Monochrome and Color
Hybrid Gamma PXLThe Hybrid Gamma PXL function on the Eizo Radiforce RX360 LCD monitor automatically distinguishes between monochrome and color images pixel by pixel, creating a hybrid display where each pixel has optimum grayscale. As a result, monochrome images such as CR and DR are displayed in the ideal grayscale that corresponds to DICOM Part 14, while color images such as those used in endoscopy, nuclear medicine, 3D rendering, and fusion imaging are faithfully reproduced corresponding to Gamma 2.2. This improves the efficiency of viewing both monochrome and color images together on one screen.
Create a Free-Flowing Work Environment
Compared to a previous model, the RX340, the monitor’s width, height, and depth were reduced by 35 mm, 39 mm, and 46 mm respectively – a total of 32% less space – saving more workspace for other tasks. Reducing the width of the monitor’s frame by approximately 70% reduces eye movement when comparing side-by-side images in a dual monitor configuration, creating a free-flowing work environment.
Achieve Clarity True to the Source Data
A medical monitor needs to be capable of high brightness in order to meet performance standards. However, in order to achieve high brightness in an LCD panel, the pixel aperture ratio has to be increased. This causes a typically unavoidable decline in sharpness. With EIZO’s unique Sharpness Recovery technology, the decrease in sharpness (MTF) is restored. This allows you to display an image that is true to the original source data safely on the monitor, even at high brightness levels.
MTF measures numerically how faithfully the panel transfers details from the original image data for viewing. When Sharpness Recovery is turned on, in the case of a 2 pixel line pair (spatial frequency of 1.182 cycles/mm) the MTF increases by approximately 54%.
Variations for Specific User Needs
The Eizo Radiforce RX360 Diagnostic LCD monitor offers anti-glare (AG) and anti-reflection (AR) screen variations to suit user environments. AG treatment is ideal for exceptionally bright environments and drastically reduces glare from ambient lighting. AR treatment is ideal for moderately-lit environments to reduce mild screen glare while maintaining crisp text and images.
Hassle-Free Multi-Monitor Configuration
Using the DisplayPort connection, you can drive several monitors in a daisy chain sequence. This allows you to configure a multi-monitor setup without the complicated hassle of excessive cabling.
Make the Precise Diagnosis
EIZO carefully measures and sets the grayscale at the factory to ensure each monitor is compliant with DICOM Part 14. Furthermore, at startup or upon wakeup, the EIZO patented drift correction function quickly stabilizes the brightness level and compensates the brightness fluctuations caused by the ambient temperature and the passage of time, allowing medical images to be faithfully reproduced with stable brightness and grayscale.
Manage Effortless Quality Control
With the RadiCS LE software (included) and Integrated Front Sensor (IFS) built into the front bezel of the Eizo Radiforce RX360, you can easily calibrate to DICOM Part 14 without having to mount, run, and remove an external sensor.
Conserve Energy While Away
A presence sensor prompts the monitor to switch to power save mode when the user is away and resumes operation upon their return to conserve power when not in use, uniting convenience with savings.
Stay Confident with Stable Brightness
EIZO’s confidence in its product quality extends to brightness stability which is also covered during the usage time specified in the warranty.
Warranty with Safety and Trust
EIZO and its authorized distributors offer a five-year full warranty.
About Eizo
EIZO, which means image in Japanese, is a visual technology company that develops and manufactures high-end display solutions. EIZO integrates hardware and software technologies with consulting, web hosting, and other services to help customers in business, graphics, gaming, medicine, maritime, air traffic control, and other fields work more comfortably, efficiently, and creatively. Headquartered in Hakusan, Japan, EIZO has R&D and manufacturing facilities in Japan, China, Germany, and the U.S., and representation in more than 80 countries.
Model Variations | RX360: Anti-Glare coating RX360-AR: Anti-Reflection coating |
---|---|
Cabinet Color | Black |
Panel | |
Type | Color (IPS) |
Backlight | LED |
Size | 54.1 cm / 21.3" |
Native Resolution | 1536 x 2048 (3:4 aspect ratio) |
Viewable Image Size (H x V) | 324.9 x 433.2 mm |
Pixel Pitch | 0.2115 x 0.2115 mm |
Display Colors | 10-bit colors (DisplayPort): 1.07 billion (maximum) colors 8-bit colors: 16.77 million from a palette of 543 billion colors |
Viewing Angles (H / V, typical) | 178° / 178° |
Brightness (typical) | 1100 cd/m2 |
Recommended Brightness for Calibration | 500 cd/m2 |
Contrast Ratio (typical) | 1500:1 |
Response Time (typical) | 12 ms (on / off) |
Video Signals | |
Input Terminals | DisplayPort x 2, DVI-D (dual link) |
Output Terminals | DisplayPort (daisy chain) |
Digital Scanning Frequency (H / V) | 31 - 127 kHz / 29 - 61.5 Hz |
USB | |
Upstream | USB 2.0: Type-B x 2 |
Downstream | USB 2.0: Type-A x 2 |
Power | |
Power Requirements | AC 100 - 240 V: 50 / 60 Hz |
Maximum Power Consumption | 74 W |
Typical Power Consumption | 34 W |
Power Save Mode | 1 W or less |
Sensor | Backlight Sensor, Integrated Front Sensor, Presence Sensor, Ambient Light Sensor |
Features & Functions | |
Brightness Stabilization | Yes |
Digital Uniformity Equalizer | Yes |
Hybrid Gamma PXL | Yes |
Preset Modes | CAL Switch |
OSD Languages | English, German, French, Italian, Japanese, Simplified Chinese, Spanish, Swedish, Traditional Chinese |
Physical Specifications | |
Net Weight | 8 kg |
Net Weight (Without Stand) | 5.2 kg |
Hole Spacing (VESA Standard) | 100 x 100 mm |
Certifications & Standards (Please contact EIZO for the latest information.) | CE (Medical Device Directive), EN60601-1, ANSI/AAMI ES60601-1, CSA C22.2 No. 601-1, IEC60601-1, VCCI-B, FCC-B, CAN ICES-3 (B), RCM, RoHS, China RoHS, WEEE, CCC, EAC |
FDA | 510(k) Clearance for General Radiography |
Dedicated Software | |
Monitor Quality Control Software RadiCS | Supported |
Supplied Accessories (May vary by country. Please contact EIZO for details.) | |
Signal Cables | DisplayPort (3 m) x 2 |
Others | AC power cord (3 m), USB cable (3 m) x 2, Utility Disk (RadiCS LE, PDF instructions for use, PDF installation manual), instructions for use |
Warranty | Five Years |
Warning: call_user_func() expects parameter 1 to be a valid callback, function 'download_file_force' not found or invalid function name in /home/hiliex.com/public_html/wp-content/plugins/woocommerce/templates/single-product/tabs/tabs.php on line 47