- Five precalibrated 10 bit look up tables selectable for diverse modalities and viewing environments.
- Freely adjustable user lookup table allowing users to set their own preferences.
- Color slider for color adjustment in the field without the loss of grayscale tones.
- Grayscale tones adjusted in the factory to meet DICOM Part 14 standard for optimum viewing of DICOM images.
- Force Mode for tailoring the monitor to even the most specialized timing requirements.
- Wide range of input support.
- 5858511, 5417438, 5746371, 5183450-2
Eizo LX1910 (LX1910-S) 19″ High Bright Color Medical LCD Display
Description
Eizo CuratOR LX1910 (LX1910-S) 19″ 1MP Color Medical Monitor
Eizo CuratOR LX1910 (LX1910-S) 19″ high-brightness color monitor for diagnosis is perfect for accurate displaying of grayscale tones as well as color images in the medical environment. The monitor accepts multiple input signals from both state-of-the-art and legacy systems. Its high contrast creates the perfect fit for most grayscale modalities and imaging systems. Typical application areas are interventional radiology, endoscopy, cardiology, and ultrasound.
Perfect Image Reproduction thanks to IPS LCD Technology
The Eizo CuratOR LX1910 (LX1910-S) LCD technology used eliminates picture geometry distortions and color spots. The Eizo CuratOR LX1910 (LX1910-S) monitor delivers flicker-free images, even at low refresh rates (60 Hz). In addition, IPS technology guarantees improved contrast values and significantly higher viewing angle stability. The result is a device that meets the highest ergonomic requirements.
Individualized Color Point Adjustment
The monitor’s default blue color location can be adjusted to individual requirements using a color slider. This enables color adjustment in the field such as when replacing a monitor. The adjustment can be performed via the On Screen Display (OSD) without external tools such as a luminance meter or calibration software.
Support of Complex Timing Requirements
Although the monitor automatically detects standard video signals, older medical devices frequently cause problems due to their unusual
timing. These special application requirements can be met using the Force Mode function.
Freely Adjustable User Lookup Table (LUT)
The Eizo CuratOR LX1910 (LX1910-S) adjustable LUT makes it possible for LUT recalculations to be initiated manually. Within this recalculation, the gamma model, luminance settings, or color parameters can be modified. The LUT is calculated via OSD menu without having to access external calibration software. The reset LUT is calculated immediately, saved in the device, and used immediately for image display. This provides the user with the ability to establish the user LUT individually without using a luminance meter.
Display of Different Signal Resolutions
The Eizo CuratOR LX1910 (LX1910-S) optimum screen resolution is 1280 x 1024 pixels. Video signals with other resolutions, common in medical technology, are automatically adapted to the screen size. Alternatively, they can be displayed in their original size (1:1).
Consistency thanks to DICOM Part 14 Factory Calibration
The Eizo CuratOR LX1910 (LX1910-S) monitor is precalibrated to meet the DICOM Part 14 standard, thereby ensuring permanently consistent image transmission. The five default look-up tables (LUTs) contain practice-based settings. They take into account the DIN 6868-157 room classes, thereby meeting current pecifications for diagnostic monitors.
Constant Luminance Regulation
An integrated brightness sensor, using EIZO fully automated brightness control, ensures fast luminance stabilization during system start and compensates for fluctuations that occur in the course of operation due to differing ambient temperatures.
Cascading multiple monitors
The integrated Loop-Through output (BNC video / SoG signal) enables connection with multiple other monitors or image archiving in the operating room.
Installation on a VESA Ceiling Suspension
Compliance with the VESA standard enables attachment to existing mounting accessories.
Versatile Positioning for Improved Ergonomics
EIZO’s highly versatile stand offers tilt, swivel and a wide height adjustment range enabling you to use the monitor with greater comfort.
Environmentally-Friendly LED Backlight
By utilizing an energy-efficient LED as a backlight, the monitor achieves a high-brightness and low power consumption at the same time. In contrast to conventional CCFL technology, LED backlighting offers a longer monitor lifespan, is free of hazardous materials, and is therefore compliant with current environmental regulations.
Customer Assurance with Medical Standards
The Eizo CuratOR LX1910 (LX1910-S) monitor meets the strictest medical, safety, and EMC emission standards.
Part Numbers:
5858511
5417438
5746371
5183450-2
About Eizo
EIZO, which means image in Japanese, is a visual technology company that develops and manufactures high-end display solutions. EIZO integrates hardware and software technologies with consulting, web hosting, and other services to help customers in business, graphics, gaming, medicine, maritime, air traffic control, and other fields work more comfortably, efficiently, and creatively. Headquartered in Hakusan, Japan, EIZO has R&D and manufacturing facilities in Japan, China, Germany, and the U.S., and representation in more than 80 countries.
Warning: call_user_func() expects parameter 1 to be a valid callback, function 'download_file_force' not found or invalid function name in /home/hiliex.com/public_html/wp-content/plugins/woocommerce/templates/single-product/tabs/tabs.php on line 47
SPECIFICATION
General |
|||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||||
Panel |
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
Video Signals |
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
USB |
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
Power |
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
Features & Functions |
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
Environmental Requirements |
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
Physical Specifications |
|||||||||||||||||||||||||
|